Products
Vacuum Pumps
Belt Driven PumpsDuoSeal 1374DuoSeal 1376DuoSeal 1380DuoSeal 1397DuoSeal 1399DuoSeal 1400DuoSeal 1402DuoSeal 1405DuoSeal 1400W-01DuoSeal 1402W-01DuoSeal 1405W-01ChemStar 1400N-90ChemStar 1402N-90ChemStar 1376NChemStar 1400NChemStar 1402NCapture CRRBelt Kit 1397ABelt Kit 1399ABelt Kit 1400ABelt Kit 1405AMajor Repair Kit 1373K-06Major Repair Kit 1376K-06Major Repair Kit 1376K-10Major Repair Kit 1380K-04Major Repair Kit 1397K-08Major Repair Kit 1399K-04Major Repair Kit 1400K-04Major Repair Kit 1400K-10Major Repair Kit 1402K-06Major Repair Kit 1402K-10Major Repair Kit 1402K-47Minor Repair Kit 1373K-05Minor Repair Kit 1376K-05Minor Repair Kit 1376K-09Minor Repair Kit 1376K-46Minor Repair Kit 1397K-07Minor Repair Kit 1380K-03Minor Repair Kit 1399K-03Minor Repair Kit 1400K-03Minor Repair Kit 1400K-09Minor Repair Kit 1402K-05Minor Repair Kit 1402K-09Minor Repair Kit 1402K-46Seal Kit 1401EDuoSeal Oil
welch-logo.png

Stop Manual Cleaning. Start Continuous Uptime

If you're running lab or industrial processes that generate condensable vapors, you already know the cost of downtime caused by clogged vacuum systems. Welch’s self-cleaning dry vacuum systems (Models 2025–2028) are designed to eliminate that problem. These units automatically purge condensates without interrupting operation, extending service intervals and protecting pump performance.

This asset page summarizes the key features, operating principles, and maintenance advantages of the Welch self-cleaning systems. It links directly to the full product manual for technical teams and operators who need detailed specs and setup instructions.

Full Manual

Get the complete technical documentation for installation, operation, and maintenance.
Self-Cleaning Dry Vacuum Systems

What Makes These Systems Self-Cleaning?

Each model integrates a purge cycle that automatically clears condensate from the vacuum lines and pump internals. The purge is triggered by a programmable timer or external signal, depending on your setup. This prevents buildup that typically leads to performance degradation or system failure.

 

Key Features by Model

ModelFlow RateUltimate VacuumPurge ControlRecommended Use
202520 lpm1 TorrManualSmall lab setups
202635 lpm0.5 TorrTimer-basedMedium throughput
202750 lpm0.1 TorrExternal signalContinuous ops
202875 lpm0.05 TorrProgrammableHigh-demand systems

 

Installation and Setup

The manual covers:

  • System layout: Diagrams for each model
  • Electrical connections: Voltage specs and wiring
  • Purge configuration: How to set purge intervals
  • Safety protocols: Pressure relief, grounding, and ventilation

Setup takes under an hour for most labs. No special tools required.

 

Maintenance and Troubleshooting

These systems are designed for minimal maintenance. The purge cycle drastically reduces the need for manual cleaning. The manual includes:

  • Filter replacement intervals
  • Diagnostics for purge failures
  • Error codes and reset procedures
  • Cleaning procedures (if needed)

FAQs

Depends on vapor load. For heavy condensables, Welch recommends every 30–60 minutes. The manual provides guidance based on application type.